Construction & Operation

Double skin 12mm high density chipboard clad to twist resistant aluminum frame with internal layers of sound reducing materials to achieve the sound insulation required. Continuous sweep seals at top and bottom of panels to minimise sound transfer.

For CAD details and technical specifications, please go to the Downloads page.


Technical Information

Acoustic Performance : Rw 30dB - Rw 45dB (Laboratory Tested) 

Panel Weight: 35kg/m2 - 45 kg/m2 (dependent upon acoustic ratings).

Maximum Opening Width: Unlimited.

Maximum Panel Height: 4000mm. 

Maximum Panel Width: 500mm - 900mm.

Panel Thickness: 80mm (nominal).

Fire Rating: Class 1 and 0 surface spread of flame are available.

Head Track and Floor System and Configuration: Bottom-rolling - heavy duty aluminium floor tracks with concealed fixings, 100mm x 10mm, finished in SAA. Designed for screed or raised floors and incorporating a top guide track. Top hung - heavy-duty aluminium head track with integral ceiling support trim 120mm x 75mm finished as standard to RAL 9010, but can be powder coated to any RAL or BS Colour. Usually without floor tracks or guides.

Mechanisms & Ironmongery: Face operated espagnolette bolts locate panels securely in position. Escutcheon finished in SAA to face of alternate panels. Recessed D ring handle finished in SAA on lead panel which usually acts as a Full Height Door. 

Jamb Details: 65mm wall posts at either end of system to match panels.

Head Fixing & Acoustic Baffling: For the Top-hung systems, Head Track is typically suspended from a structural steel I-Beam or concrete soffit with galvanised steel rods at 450mm - 600mm centres similar to the series 100 system. Can also be fitted directly to soffit. For the bottom-rolling system, a 'top guide track' is necessary to maintain the wall in a vertical position. Any acoustic baffling to ceiling and/or floor voids is designed to maintain the acoustic performance of the wall system.

Panel Construction: Double skin 12mm high density chipboard clad to twist-resistant aluminum frame with internal layers of sound-reducing materials to achieve the sound insulation rating required. Continuous contact sweep seals at top and bottom of panels to minimise sound transfer. 

Panel Finishes (Including but not limited to): Melamine, Laminate, Wood Veneer, Drywipe, Magnetic Drywipe, factory-applied paint, MDF Primed (ready for decorations by others), Steel Facing, pin board and Mirrors. Vision Panels to Minimise sound transfer.

Standard Edge Profiles / Vertical Joints: Semi-concealed edge profiles finished in SAA as standard, but can be powdered coated to any RAL or BS colour. Profiles include hinges and bulb seals for acoustic integrity.

Access Doors: Leading element can act as Full Height Pass Door complete with recessed D handle finished in SAA (with optionallock)

Intersection of Multiple Systems: Specification can include walls meeting to form corner junctions or 'T' or 'L' shape systems.